The office headquarter building, TLY Pte Ltd, that is located at Buona Vista, was built in 1998 and has not been obtaining any Green Mark Award since then.

Since the company are currently targeting and wanting to achieve the Green Mark Gold for the single tenant building, based on the information as mentioned above, the recommended version of BCA Green Mark assessment criteria will be the Existing Non-Residential Building Version 3.0 (ENRB V3). Question 2: The BCA Green Mark certification process for the office headquarter building to obtain Green Mark Gold Award for Existing Non-Residential Building Version 3.0 criteria will be as follow: Application – This initial process will require the submission of application that is to be done online at BCA Website with all the relevant supporting documents for certification of the Green Mark Gold Award upon any finalization of sustainable practices to be achieved. Through account registration in the BCA Green Mark Online Website and logging in with SingPass ID or GM ID, the completion of the online application, including Annex A, are to be submitted together with the Non-Residential Existing Buildings Green Mark form. After the acceptance of fees being paid and application by BCA, the Green Mark Assessor will be assigned to the building. Pre-Assessment – An audit for pre-assessment are recommended to be carried out during this stage so as to give the building owner, project team and relevant stakeholders, a better understanding of the required criteria for the building to achieve Green Mark Gold Certification level.

This will involve having a formal meeting with BCA and are usually conducted through presentation, so as to confirm that the project teams are heading towards the correct direction for the certification and award sought. Actual Assessment – This stage will involve detail checking of documentary evidences and calculations, so as to confirm if the building has met all the criteria (including pre-requisite requirements) to achieve the Gold certification level. Letter of award displaying the BCA Green Mark Rating will be issued after fulfilling all the necessary requirements as mentioned above. Verification – Site verification audit will be conducted by BCA at this stage so as to determine that the green features, which resulted in the Gold Certification and review of delivery records for any updated documents, are fully compliance with the required BCA Green Mark standard. After which, during this final stage of the certification process, BCA Green Mark Gold Certificate will be issued and it is valid for 3 years.

Question 3: The BCA Green Mark assessment fee for certification of the office headquarter building will be as follow: Under the Existing Building Category for Medium and above (GFA more than 5,000 m2/Sq m), the assessment fee for certification will be S$8,900 for the first GFA of 15,000 m2/Sq m and S$0.15 for every subsequent m2/Sq m. Therefore, with Gross Floor Area (GFA) at 37,800 m2/sq m of the entire 15-storey office HQ building & 2-storey basement, the calculation/costing will be S$8,900 + (subsequent 22,800 m2/Sq m x S$0.15 = S$3,420) = S$12,320 (Excluding GST). The final fee computation inclusive of 7% GST will be S$12,320 + (7/100 x S$12,320 = S$862.40) = S$13,182.40/- (Including 7% GST). The screen shot of the BCA website assessment fee guide that the above computation/calculation was derived from is as shown below: Question 4, 5 & 6: Category Available Points Current Points (Question4) Proposed Additional Points (Question5) Total Points (Question4 and 5) Reasons (Question6) Part 1 Energy Efficiency 1-1 Thermal Performance of Building Envelope – ETTV 5 0 0 0 Information on building wall and glazing details are not available. 1-2 Air-Conditioning System 32 1 18.33 19.33 Current Points: Sensors used to maintain concentration of carbon dioxide = 1 Point Proposed Points: Because of Pre-Requisite Requirements and to achieve Gold Award as follow: – Achieving the current plant efficiency of 0.97 kW/Ton to 0.75 kW/ton (Pre-Requisite) = 14 Point Improving 0.75 kW/ton to 0.70 kW/ton (Gold Standard) = 2.33 Point Install permanent measuring system for monitoring chilled water system (Pre-Requisite) = 1 Point Using Heat balance substantiating test for verification of chilled water system (Pre-Requisite) = 1 Point 1-3 Natural Ventilation / Mechanical Ventilation 0 0 0 Non air-conditioned spaces are not more than 10% of the building total GFA. 1-4 Artificial Lighting 13 2.04 0 2.04 Current Points: Total Reference (SS530) Power Consumption of 469,201 W minus Total Existing Power Consumption of 437,248 W = 31,953 W %Saving – 31,953/469,201 W x 100% = 6.8% Point score – 0.3 x 6.8% = 2.04 points 1-5 Ventilation in Car Park 4 2 0 2 Current Points: Mechanical Ventilation with CO sensors for Car park Estimated Area of 6000 m2 = 2 Points 1-6 Ventilation in Common Areas 5 3.5 0 3.5 Current Points: Natural Ventilation in Toilets = 1.5 Points Natural Ventilation in Staircases = 1.5 Points Mechanical Ventilation in Lift Lobbies = 0.5 Points 1-7 Lifts and Escalators 2 1 0 1 Current Points: Lift with VVVF motor drive and sleep mode = 1 Points 1-8 Energy Efficiency Practices and Features 12 3.3 0 3.3 Current Points: EEI is 6,692,000 kWh per year divide by 37,000m2 GFA x 55hrs/60hrs(7am-7pm) = 162.34 kWh/m2 per year (1 Point) VSD of Chiller 1 – 4 (4 x Chiller), certified by SGBC = 2 Points Auto-Condenser tube cleaning system certified by SGLS = 0.5 Point (BUT Maximum 2 Points for above) Photo Sensors & Motion Sensors of Light fittings that saves 9,800 kWh of electricity annually – 9800 kWh/6,692,000 kWh x 100% = 0.15 % Saves, Therefore, 0.15% x 2 points = 0.3 Points 1-9 Energy Policy and Management 1 0 1 1 Proposed Points: As Buffer for Pre-Requisite Requirement in Energy Efficiency Category to achieve Gold Standard (Minimum 35 Points): – Regular Energy Policy review with top management = 0.5 Point Energy efficiency improvement plans for the next 3 years to achieve energy target set = 0.5 point 1-10 Renewable Energy 15 4.1 0 4.1 Current Points: Grid-tie photovoltaic installed on roof that can produce renewable energy of 55 MWh (55,000 kWh) – 55,000 kWh/6,692,000 kWh x 100% = 0.82%, Therefore, 0.82% x 5 points = 4.1 Points Sub-Total for Part 1 89 16.94 19.33 36.27 Part 2 Water Efficiency 2-1 Water Monitoring 4 2 0 2 Current Points: Monitoring of major water consumption through sub-meters installed – 1 point Monitoring water consumption monthly by maintenance team, as being tasked by management – 1 Point 2-2 Water Efficient Fittings 12 9 0 9 Current Points: Obtained PUB WEB Certificate – 9 Points 2-3 Alternative Water Sources 3 0 0 0 Information on utilizing alternative water sources is not available.

2-4 Water Efficiency Improvement Plans 1 0 1 1 Proposed Points: As buffer for total points and it is cost effective – Water efficiency improvement plans for the next 3 years to achieve water target set = 1 point 2-5 Irrigation System and Landscaping 2 1 0 1 Current Points: Automatic water efficient drip irrigation system to rain sensor for 100% of landscape areas – 1 Point 2-6 Cooling Towers 2 1 0 1 Current Points: Achieve 8 cycles of concentration in the cooling tower water system treatment – 1 Point Sub-Total for Part 2 24 13 1 14 Part 3 Sustainable Operation and Management 3-1 Building Operation and Maintenance 4 3.5 0 3.5 Current Points: Company Environmental Policies in place – 1 Point Green Guide for occupants such as good green practice sent to all staff digitally & Green Corner is set-up at main lobby for visitors – 1 Point One certified GMFM is the company/building management team – 0.5 Point ISO 14000 certified – 1 Point 3-2 Post Occupancy Evaluation 3 0 2 2 Proposed Points: As buffer for total points & it is cost effective to achieve – Conduct post occupancy survey – 2 Points 3-3 Waste Management 7 5 0 5 Current Points: Providing recycling bins at every floor – 2 Points Dedicated room as storage area for recyclable waste is provided – 1 Point To establish continuous improvement targets by the management – 2 Points 3-4 Sustainable Products 8 0 0 0 Information on environmental friendly product and its weightage are not available. 3-5 Greenery 10 1 0 1 Current Points: GnP Value of 0.9 – 1 Point 3-6 Environmental Protection 3 2 0 2 Current Points: Green Procurement policies in place – 1 Point Leak detection system of refrigerant are in use – 1 Point 3-7 Green Transport 4 2.5 0 2.5 Current Points: Good access to MRT station as it is located next to building – 1 Point Building is linked through covered walkway to MRT station – 1 Point 10 x Bicycles parking lots available – 0.5 Point Sub-Total for Part 3 39 14 2 16 Part 4 Indoor Environmental Quality 4-1 Indoor Air Quality Performance 8 1 5 6 Current Points: All offices at every floor are equip with room temperature display – 1 Point Proposed Points: As a Pre-Requisite requirements – Full IAQ Audit need to be conducted – 4 Points IAQ Management plan to be implemented effectively – 1 Point 4-2 Indoor Air Pollutants 2 1 0 1 Current Points: Certified by SGLS, water based paint is used – 1 Point 4-3 Lighting Quality 5 5 0 5 Current Points: SS531 Standard for all lighting level are in use – 1 point Task Lights are equipped at all workstation – 2 Points All fluorescent lighting with high frequency ballast are in use – 2 Points 4-4 Thermal Comfort 2 1 0 1 Current Points: Temperature maintained at 25 degree Celsius (it is between 22.5 to 25.5) & relative humidity is at 60% (it is below 70%) – 1 Point 4-5 Internal Noise Level 1 0 0 0 Information on internal noise level is not available Sub-Total for Part 4 18 8 5 13 Part 5 Other Green Features 5-1 Green Features & Innovations 10 0.5 0.5 1 Current Points: Use of UV emitters at all AHU – 0.5 Point Proposed Points: During the routine termite treatment by Pest Control Company for the building, using of non-chemical for the treatment should be might as well be necessary – 0.5 point Sub-Total for Part 5 10 0.5 0.5 1 Total Score (Part 1 + 2 + 3 + 4 +5): 180 52.44 27.83 80.27 Through fulfilling all the Pre-Requisite Requirements & gaining some of the proposed points as buffer, targeting the total points of 80.27 will enable TLY Pte Ltd to achieve the BCA Green Mark Gold Award for their HQ Building. Reference BCA. (Jan, 2016). Green Mark Certification Standard for Existing Building – GM Version 3.0. Retrieved Nov, 2018, https://www.bca.gov.sg/GreenMark/others/GM_Existing_Building_Certification_Standard.pdfBCA.

(Oct, 2018). BCA Green Mark Assessment Fees for Building Projects in Singapore. Retrieved Nov, 2018, https://www.bca.gov.sg/greenmark/others/GMfees_01102018.pdfBuilding and Construction Authority – BCA Green Mark for Existing Non-Residential Buildings (Version 3.0) FMT311 Green Building Assessment Standards Study Guide by SUSS, 2016, Release V1.3